Complete Heater Kits for Full Depth Points 113lb Flat Bottom Rail with Slotted Chair Blocks – UK Railtrack Infrastructure, Heater voltage 110/120 Volts. | |||
---|---|---|---|
Part Reference | PADS No. | Description | Point Size |
GBK 120/RT/113/05 | 055/020852 | 0.5m 120 Volt Heater and Accessories (Pack of 10) | N/A |
GBK 120/RT/113/A4 | 055/020829 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | AV |
GBK 120/RT/113/B4 | 055/020830 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | BV |
GBK 120/RT/113/C5 | 055/020831 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | CV |
GBK 120/RT/113/D6 | 055/020832 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | DV |
GBK 120/RT/113/E8 | 055/020833 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | EV |
GBK 120/RT/113/F10 | 055/020834 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | FV |
GBK 120/RT/113/SG | 055/020835 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | SGV |
GBK 120/RT/113/G14 | 055/020836 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | GV |
GBK 120/RT/113/H18 | 055/020837 | 113lb 120 Volt Full Depth Heater Kit with slotted J Blocks | HV |
Note: When ordering for use in conjunction with clamplocks please add the suffix of C. I.e., GBK 120/RT/U54/G14 becomes GBK 120/RT/U54/G14C when kit includes clamplocks. Also available: Heater Kits with 230 Volt rated heaters All of the above Heater Kits are available in 230 Volts. When ordering please substitute the GBK 120 suffix with GBK 230. I.e., for 230 Volt version of GBK 120/RT/113/A4 order GBK 230/RT/113/A4 | |||
Complete Heater Kits for Full Depth Points 113lb Flat Bottom Rail with Non-Slotted Chair Blocks – UK Railtrack Infrastructure, Heater Voltage 110/120 Volts. | |||
GBK 120/RT/113/05 | 055/020852 | 0.5m 120 Volt Heater and Accessories (Pack of 10) | N/A |
GBK 120/RT/113/AV | 055/020820 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | AV |
GBK 120/RT/113/BV | 055/020821 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | BV |
GBK 120/RT/113/CV | 055/020822 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | CV |
GBK 120/RT/113/DV | 055/020823 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | DV |
GBK 120/RT/113/EV | 055/020824 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | EV |
GBK 120/RT/113/FV | 055/020825 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | FV |
GBK 120/RT/113/SGV | 055/020826 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | SGV |
GBK 120/RT/113/GV | 055/020827 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | GV |
GBK 120/RT/113/HV | 055/020828 | 113lb 120 Volt Full Depth Heater Kit with non-slotted J Blocks. | HV |
Note: When ordering for use in conjunction with clamplocks please add the suffix of C. I.e., GBK 120/RT/113/GV becomes GBK 120/RT/113/GVC when kit includes clamplocks. Also available: Heater Kits with 230 Volt rated heaters All of the above Heater Kits are available in 230 Volt. When ordering please substitute the GBK 120 suffix with GBK 230. I.e., for 230 Volt version of GBK 120/RT/113/A4 order GBK 230/RT/113/A4 | |||
Complete Heater Kits for Shallow Depth Points with UIC54 Rail Section Heater voltage 120 Volts. | |||
GBK 120/RT/U54/A4 | 055/020838 | UIC54 120 Volt Shallow Depth Heater Kit | AV |
GBK 120/RT/U54/B4 | 055/020839 | UIC54 120 Volt Shallow Depth Heater Kit | BV |
GBK 120/RT/U54/C5 | 055/020840 | UIC54 120 Volt Shallow Depth Heater Kit | CV |
GBK 120/RT/U54/D6 | 055/020841 | UIC54 120 Volt Shallow Depth Heater Kit | DV |
GBK 120/RT/U54/E8 | 055/020842 | UIC54 120 Volt Shallow Depth Heater Kit | EV |
GBK 120/RT/U54/F10 | 055/020843 | UIC54 120 Volt Shallow Depth Heater Kit | FV |
GBK 120/RT/U54/SG | 055/020844 | UIC54 120 Volt Shallow Depth Heater Kit | SGV |
GBK 120/RT/U54/G14 | 055/020845 | UIC54 120 Volt Shallow Depth Heater Kit | GV |
GBK 120/RT/U54/H18 | 055/020846 | UIC54 120 Volt Shallow Depth Heater Kit | HV |
Note: When ordering for use in conjunction with clamplocks please add the suffix of C. I.e., GBK 120/RT/U54/G14 becomes GBK 120/RT/U54/G14C when kit includes clamplocks. Note: When ordering for use in conjunction with HPSS point machines please replace the length suffix with H. I.e., GBK 120/RT/U54/G14 for HPSS becomes GBK 120/RT/U54/GH. Also available: Heater Kits with 230 Volt rated heaters All of the above Heater Kits are available in 230 Volt. When ordering please substitute the GBK 120 field with GBK 230. I.e., for a 230 Volt version of GBK 120/RT/U54/A4 order GBK 230/RT/U54/A4. | |||
Complete Heater Kits for Shallow Depth Points RT60 (UIC60) Rail Section Heater Voltage 120 Volts. | |||
GBK 120/RT/U60/A5 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | AV | |
GBK 120/RT/U60/B5 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | BV | |
GBK 120/RT/U60/C6 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | CV | |
GBK 120/RT/U60/D7 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | DV | |
GBK 120/RT/U60/E9 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | EV | |
GBK 120/RT/U60/F11 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | FV | |
GBK 120/RT/U60/SG14 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | SGV | |
GBK 120/RT/U60/G16 | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | GV | |
GBK 120/RT/U60/H | RT60 (UIC60) 120 Volt Shallow Depth Heater Kit | HV | |
Note: When ordering for use in conjunction with clamplocks please add the suffix of C. I.e., GBK 120/RT/U60/G16 becomes GBK 120/RT/U60/G16C when kit includes clamplocks. Note: When ordering for use in conjunction with HPSS point machines please replace the length suffix with H. I.e., GBK 120/RT/U60/G16 for HPSS becomes GBK 120/RT/U60/GH. Also available: Heater Kits with 230 Volt rated heaters All of the above Heater Kits are available in 230 Volts. When ordering please substitute the GBK 120 suffix with GBK 230. I.e., for 230 Volt version of GBK 120/RT/U60/A5 order GBK 230/RT/U60/A5 | |||
Complete Heater Kits for Bullhead Rail Points, UK Railtrack, and London Underground Ltd Infrastructure. | |||
GBK 120/RT/95BH/A | 95lb 120 Volt Bullhead Heater Kit | AV | |
GBK 120/RT/95BH/B | 95lb 120 Volt Bullhead Heater Kit | BV | |
GBK 120/RT/95BH/C | 95lb 120 Volt Bullhead Heater Kit | CV | |
GBK 120/RT/95BH/D | 95lb 120 Volt Bullhead Heater Kit | DV | |
Note: When ordering for use in conjunction with clamplocks please add the suffix of C. I.e., GBK 120/RT/95BH/D becomes GBK 120/RT/95BH/DC when kit includes clamplocks. Also available: Heater Kits with 230 Volt rated heaters All of the above Heater Kits are available in 230 volts. When ordering please substitute the GBK120 suffix with GBK230. I.e., for 230-volt version of GBK 120/RT/95BH/A order GBK 230/RT/95BH/A |