Glands
Graybar have a range of heatshrinkable glands, type CES, stainless steel adaptor glands, brass adaptor glands, brass compresson glands type CW and A2, cable sealing glands and dome top glands.
Products
PADS Approved
-
Heatshrinkable Cable Entry Glands - Type CES
Standard heatshrinkable cable entry support and sealing gland fitted with range taking heavy duty, sealant lined heatshrinkable collar, ‘O’ ring, and male nylon bush.
Part
Reference
PADS No.
Cable Range
Max. Plate
Thickness
Entry Hole
Diameter
CES 1
054/109179
3mm to 12mm
6mm
25.5mm (1”)
CES 2
054/109175
6mm to 17mm
6mm
25.5mm (1”)
CES 3
054/109176
12mm to 28mm
8mm
35mm (1.4”)
CES 4
054/109164
19mm to 40mm
10mm
51mm (2”)
CES 5
054/109181
36mm to 65mm
18mm
88mm (3.5”)
CES 2
-
Heatshrinkable Stainless Steel Adaptor Glands
Type CES Heatshrink body fitted with stainless steel adapter designed to fit selected railway equipment
Part Reference
PADS No.
Application
Max. Cable
Dia.
Max Gland
Inside Dia.
Thread
Length
Thread
TYpe
GBK2020
054/037051
Post Mounted Telephones Etc.
14mm
14.5mm
15mm
20mm conduit
GBK2021
054/037056
Old Style Treadle Switch.
14mm
14mm
14.5mm
M18
GBK2022
054/001002
Westinghouse Impedance Bonds Etc.
15mm
16mm
20mm
½” BSP
GBK2023
054/037055
Adtranz Ground Signals
27mm
28mm
15mm
1” BSP
GBK2024
054/037057
Westinghouse ‘63’ Point Machine
20mm
21mm
15mm
¾” BSP
GBK2025
054/001003
Alstom Type Signals
24mm
25mm
20mm
38mm conduit
GBK2026
054/037059
Alstom ‘2000’ Type Point Machine
24mm
25mm
20mm
32mm conduit
GBK2027
054/037050
Post Telephones & Others
14mm
14.5mm
15mm
20mm conduit
GBK2028
054/001004
Track Auto Warning System
24mm
25mm
10mm
32mm conduit
GBK2029
054/001001
Type 3 Impedance Bond
13mm
13.4mm
20mm
M18
GBK2030
054/037058
Impedance Bonds / AWS Inductor
18mm
19mm
20mm
25mm conduit
GBK2031
054/001005
Wheel Counter (F.R.E.D.) Etc.
14mm
14.5mm
12mm
20mm conduit
GBK2032
054/037067
AWS Etc. & Ext. Thread Fixing
14mm
14.5mm
35mm
20mm conduit
GBK2033
054/037068
Detector Box / Switch Etc.
18mm
19mm
25mm
25mm conduit
GBK1407
~
Clamplock Small Hole
26mm
27mm
25mm
M30
GBK1409
~
Clamplock Large Hole
28mm
29mm
6+5mm shoulder
M32
GBK1173
~
DLR Point Detection Box
25mm
26mm
15mm
M32
GBK2020
GBK2021
GBK2022
GBK2023
GBK2024
GBK2027
GBK2028
GBK2029
GBK2030
GBK2031
GBK2032
-
Heatshrinkable Brass Adaptor Glands
Type CES Heatshrink body fitted with brass adapter designed to fit selected railway equipment.
Part Reference
PADS No.
Application
Max. Cable
Dia.
Max Gland
Inside Dia.
Thread
Length
Thread
TYpe
GBK1621 054/000092
Type 2 & 3 Impedance Bonds / AWS Inductor
18mm
19mm
30mm
M22
GBK1622
054/000093
AWS Suppressor Inductor
18mm
19mm
42mm
M22
GBK1623
054/000094
Type 2 & 3 Impedance Bond / Point Heater Transformers
15mm
16mm
20mm
M18
GBK1624
054/000095
Type 2 Impedance Bond / Supplementary Detector Box / Point Heater Transformers, Etc.
20mm
21mm
30mm
M25
GBK1625
054/000096
Electro Hydraulic Power Packs / Alstom HW Point Machines / Point Heater Transformers
25mm
26mm
25mm
M30
GBK1626
054/000097
Type PL1W, PL1R and PL2R Signals / Accumulator Units, Etc.
25mm
26mm
12mm
M30
GBK1627
054/000098
Detector Boxes / Treadle Switches / P3 Impedance Bonds / Controllers / Point Machines / Etc.
28mm
28mm
6+5mm
M32
GBK1628
054/000099
DAC & RACAL Weatherproof Telephones
13.5mm
14mm
25mm
M17.5
Rail Equipment Cable Entry apertures may vary depending on the equipment age, therefore it is highly recommended that this be taken into account when selecting a suitable gland.
GBK1621
GBK1622
GBK1623
GBK1624
GBK1625
GBK1626
GBK1627
-
Brass Compression Glands Type 'CW' & 'A2'
CW type brass gland kits are suitable for plastic or rubber insulated, single wire armoured cables in most climate conditions. Terminates and secures cable armouring and outer seal grips sheath of cable, thus ensuring mechanical strength and earth continuity. Weatherproof. Supplied with steel locknut, earth tag and shroud.
Part
Reference
PADS No.
Ref
Min Cable
Dia. mm
Max Cable
Dia. mm
GBK1654 054/138803
CW20S
8.0
15.8
GBK1684 ~
CW20
11.7
20.8
GBK1685 ~
CW25
17.0
27.2
GBK1655
~
CW32
23.5
33.5
GBK1686
~
CW40
29.0
39.9
GBK1687
~
CW50S
39.8
47.0
GBK1688
~
CW50
39.5
52.6
GBK1689
~
CW63S
50.0
60.3
GBK1690
~
CW63
51.3
65.3
A2 type brass gland kits are suitable for plastic or rubber insulated, single wire unarmoured cables in most climate conditions. Supplied with steel locknut, earth tag and shroud.
Part
Reference
PADS No.
Ref
Min Cable
Dia. mm
Max Cable
Dia. mm
GBK1691
~
A2 20S
8.0
11.5
GBK1692
~
A2 20
11.0
13.5
GBK1693
~
A2 25
13.0
19.5
GBK1694
~
A2 32
19.0
25.5
GBK1695
~
A2 40
25.0
32.0
GBK1696
~
A2 50S
31.5
37.0
GBK1697
~
A2 50
36.5
43.0
GBK1698
~
A2 63S
42.5
50.0
GBK1699
~
A2 63
49.5
55.0
-
Heatshrinkable Cable Sealing Glands & Dome Top Glands
GrayBar cable sealing glands provide a means for fitting cables into waterproof enclosures using standard ISO fittings. Installation of the heatshrink assembly to the cable is accomplished away from the installed sealing gland body, preventing heat damage to the enclosure, or to other cables in close proximity.
Replacement heatshrink parts can be ordered separately, if required.
Part
Reference
PADS No.
Cable Range/Dimensional Detail
GBK1410
054/029073
Cable Dia 5mm – 16mm
Hole size 25mm, Gland Body 32mmGBK1410R
054/078037
Replacement Heatshrink Unit for GBK1410
GBK1404
054/029074
Cable Dia 6mm – 22mm
Hole size 32mm, Gland Body 42mmGBK1404R
054/078038
Replacement Heatshrink Unit for GBK1404
Dome Top Nylon Glands
GrayBar cable entry glands are manufactured from a high specification moulded material which is ideally suited to the Railway environment. The multiple thread makes for secure and rapid assembly while the neoprene seal provides a perfect watertight seal to IP68.
Part
Reference
PADS No.
Cable Range/Dimensional Detail
GBK1740 ~
Cable size 6-12mm / 20mm Hole
GBK1741
~
Cable size 9-17mm / 25mm Hole
GBK1742
~
Cable size 18-25mm / 32mm Hole
GBK1743
~
Cable size 22-32mm / 40mm Hole
Other sizes are available please call with your requirements
GBK1404